Each DUT is individually completely isolated.
[Request Overview]
Code | Item | Request value | Example | Remarks |
RO11 | Number of DC monitoring | 3 | Max : 3 | |
RO12 | Number of AC monitoring | 1 | Max : 3 | |
RO13 | Number of Digital control | 2 | Max : 5 | |
RO14 | Number of I2C monitoring | 2 | Max : 8 |
[Detail for DC Moitoring]
Code | Item | Request value | Example | Remarks |
DM11 | Number of DUTs for DC monitoring | 3 | Max : 4 (includeing AC monitoring) |
|
DM21 | Voltage range of DUT#1 | 0~50 V | Max : 200 V | |
DM22 | Current range of DUT#1 | -3000 ~ +3000 mA | Max : 10000 mA | |
DM23 | Voltage range of DUT#2 | 0~5 V | Max : 200 V | |
DM24 | Current range of DUT#2 | -1000 ~ +1000 mA | Max : 10000 mA | |
DM25 | Voltage range of DUT#3 | 0~12 V | Max : 200 V | |
DM26 | Current range of DUT#3 | -2000 ~ +2000mA | Max : 10000 mA | |
DM27 | DC OPEN/CLOSE control | Yes | Yes or No Only 1 port controlled |
|
[Detail for AC Monitoring]
Code | Item | Request value | Example | Remarks |
AM11 | Number of DUTs for AC monitoring | 2 | Max : 4 (including DC monitoring) |
|
AM21 | Voltage range of DUT#1 | 220 VAC | Max : 220 VAC | |
AM22 | Current range of DUT#1 | -1000 ~ +1000 mA | Max : 10000 mA | |
AM23 | Voltage range of DUT#2 | 110 VAC | Max : 220 VAC | |
AM24 | Current range of DUT#2 | -3000 ~ +3000 mA | Max : 10000 mA | |
AM25 | AC OPEN/CLOSE control | "Yes" | "Yes" or "No" Only 1 port controlled |
[Detail for Digital Control]
Code | Item | Request value | Example | Remarks |
DC11 | Number of control port | 3 | Max : 5 | |
DC21 | Output voltage of port#1 | 12 V | 3.3, 5 and 12V | |
DC22 | Max current of port#1 | 100 mA | 0 ~ 1000 mA | |
DC23 | Output voltage of port#2 | 5 V | 3.3, 5 and 12V | |
DC24 | Max current of port#2 | 200 mA | 0 ~ 1000 mA | |
DC25 | Output voltage of port#3 | 3.3 V | 3.3, 5 and 12V | |
DC26 | Max current of port#3 | 100 mA | 0 ~ 1000 mA |
[Detail for I2C Monitoring]
Code | Item | Request value | Example | Remarks |
IC11 | Number of DUTs for SPI monitoring | 2 | ||
IC12 | Configuration byte of DUT#1 | 0x3A | Hexa-decimal | |
IC13 | Read byte of DUT#1 | 0xB5 | Hexa-decimal | |
IC14 | Number of bytes to be read for DUT#1 | 1 | ||
IC15 | Configuration byte of DUT#1 | 0x86 | Hexa-decimal | |
IC16 | Read byte of DUT#1 | 0x62 | Hexa-decimal | |
IC17 | Number of bytes to be read for DUT#1 | 3 | ||
* Voltage value for each DUT should be specified. |
반응형
'BilientSevices > MeasurementSystem[BMS]' 카테고리의 다른 글
[BiliMon] PCB Design for BiliMon244 (0) | 2024.05.17 |
---|---|
[BiliMon] VI Address Codes (0) | 2024.05.12 |
[BiliMon] Circuit for 4 Channel VI Monitor (0) | 2024.05.06 |
[BiliMon] Monitoring App. for Web, Ver.0.1 (0) | 2024.05.05 |
[BiliMon] Monitoring App for BLE, Ver.0.1 (0) | 2024.05.04 |
반응형
250x250
최근에 올라온 글
최근에 달린 댓글
- Total
- Today
- Yesterday
링크
TAG
- Video
- 치매
- 심심풀이치매방지기
- 혁신
- 배프
- 빌리언트
- 전압
- 치매방지
- 전류
- 허들
- bilient
- 절연형
- 티스토리챌린지
- 오블완
- 둎
- Innovations&Hurdles
- Hurdles
- 심심풀이
- Innovations
- 혁신과허들
- DYOV
- ServantClock
- 아두이노
- Innovation&Hurdles
- arduino
- image
- 전압전류모니터링
- badp
- Decorator
- BSC
일 | 월 | 화 | 수 | 목 | 금 | 토 |
---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | |||
5 | 6 | 7 | 8 | 9 | 10 | 11 |
12 | 13 | 14 | 15 | 16 | 17 | 18 |
19 | 20 | 21 | 22 | 23 | 24 | 25 |
26 | 27 | 28 | 29 | 30 | 31 |
글 보관함