BilientSevices/MeasurementSystem[BMS]
[BiliMon] Request Form, Ver.0.1
inhae
2024. 5. 11. 03:00
Each DUT is individually completely isolated.
[Request Overview]
| Code | Item | Request value | Example | Remarks |
| RO11 | Number of DC monitoring | 3 | Max : 3 | |
| RO12 | Number of AC monitoring | 1 | Max : 3 | |
| RO13 | Number of Digital control | 2 | Max : 5 | |
| RO14 | Number of I2C monitoring | 2 | Max : 8 |
[Detail for DC Moitoring]
| Code | Item | Request value | Example | Remarks |
| DM11 | Number of DUTs for DC monitoring | 3 | Max : 4 (includeing AC monitoring) |
|
| DM21 | Voltage range of DUT#1 | 0~50 V | Max : 200 V | |
| DM22 | Current range of DUT#1 | -3000 ~ +3000 mA | Max : 10000 mA | |
| DM23 | Voltage range of DUT#2 | 0~5 V | Max : 200 V | |
| DM24 | Current range of DUT#2 | -1000 ~ +1000 mA | Max : 10000 mA | |
| DM25 | Voltage range of DUT#3 | 0~12 V | Max : 200 V | |
| DM26 | Current range of DUT#3 | -2000 ~ +2000mA | Max : 10000 mA | |
| DM27 | DC OPEN/CLOSE control | Yes | Yes or No Only 1 port controlled |
|
[Detail for AC Monitoring]
| Code | Item | Request value | Example | Remarks |
| AM11 | Number of DUTs for AC monitoring | 2 | Max : 4 (including DC monitoring) |
|
| AM21 | Voltage range of DUT#1 | 220 VAC | Max : 220 VAC | |
| AM22 | Current range of DUT#1 | -1000 ~ +1000 mA | Max : 10000 mA | |
| AM23 | Voltage range of DUT#2 | 110 VAC | Max : 220 VAC | |
| AM24 | Current range of DUT#2 | -3000 ~ +3000 mA | Max : 10000 mA | |
| AM25 | AC OPEN/CLOSE control | "Yes" | "Yes" or "No" Only 1 port controlled |
[Detail for Digital Control]
| Code | Item | Request value | Example | Remarks |
| DC11 | Number of control port | 3 | Max : 5 | |
| DC21 | Output voltage of port#1 | 12 V | 3.3, 5 and 12V | |
| DC22 | Max current of port#1 | 100 mA | 0 ~ 1000 mA | |
| DC23 | Output voltage of port#2 | 5 V | 3.3, 5 and 12V | |
| DC24 | Max current of port#2 | 200 mA | 0 ~ 1000 mA | |
| DC25 | Output voltage of port#3 | 3.3 V | 3.3, 5 and 12V | |
| DC26 | Max current of port#3 | 100 mA | 0 ~ 1000 mA |
[Detail for I2C Monitoring]
| Code | Item | Request value | Example | Remarks |
| IC11 | Number of DUTs for SPI monitoring | 2 | ||
| IC12 | Configuration byte of DUT#1 | 0x3A | Hexa-decimal | |
| IC13 | Read byte of DUT#1 | 0xB5 | Hexa-decimal | |
| IC14 | Number of bytes to be read for DUT#1 | 1 | ||
| IC15 | Configuration byte of DUT#1 | 0x86 | Hexa-decimal | |
| IC16 | Read byte of DUT#1 | 0x62 | Hexa-decimal | |
| IC17 | Number of bytes to be read for DUT#1 | 3 | ||
| * Voltage value for each DUT should be specified. | ||||
반응형